Air Conditioner Temperature Probes
We are one of the leading names in the industry that offers a qualitative range of Air Conditioner Temperature Probes and Air Conditioning Sensor Probes. These are manufactured using quality raw materials and precision techniques of production. We also offer these in varied specifications to meet the requirements of our clients. |
|
Applications
- Surface temperature measurement
- e.g: on housings and pipes
- Inverters, UPS, Air Conditioners
- Water Heaters, Air Warmers
- Refrigerators, Freezers
- Washing Machines, Driers, Boilers etc…
- Probe: copper, brass with or without plating.
Features
- High accuracy
- Easy mounting
- Good thermal coupling through metal tag
- Thermistors encapsulated in Compact Plastic Case/SS tubes (5x25/6x25)
- Black Twin Parallel Wire
Options available on request
- Alternative resistance ratings
- Rated temperatures,
- Tolerances
- And Lead Lengths
- Terminal Connectors Available upon Customer requirement
|
|
Product Series Code |
Resistance at 25°C |
Resistance Tolerance |
Encapsulation |
Type of Lead |
Total Length |
Beta(β) Constant |
STTS |
103 |
R5 |
MT |
E |
L152 |
3977 |
Temperature Sensor type NTC Thermistor |
10 x 103 Ω (10kΩ) |
±5% |
Metal Tube |
Twin Parallel Wire
|
Total Length = 15 x 102 mm (1500 mm) |
Beta(β) Value = 3977K |
Reliability Data
Test |
Standard |
Test Conditions |
Change in R25 (ΔR25/R25) |
Remarks |
Storage in dry heat |
IEC 68-2-2 |
Storage at upper category temperature T: 140 °C t: 500 h |
< 1% |
No visible damage |
Storage in damp heat, steady state |
IEC 68 - 2- 3 |
Temperature of air:40 °C Relative humidity of air: 93 % Duration: 56 days |
< 1% |
No visible damage |
Rapid temperature cycling |
IEC 68 - 2- 14 |
Lower test temperature:– 55 °C Upper test temperature: 155 °C Number of cycles: 5
|
< 1% |
No visible damage |
Long-term stability (empirical value) |
|
Temperature: + 100°C Duration: 2000 h |
< 2% |
No visible damage |
Range of Products
Resistance at 25° C |
Beta Value |
R - T DATA |
Resistance Tolerance |
Type of Lead |
1000 Ω |
3560 K |
R-T |
±1%, ±2%, ±5% |
0.16 x7 Mm Conductor Diameter PTFE Insulated Multistrand Copper Wire Yellow/Blue Or FEP wire Multistrand Blue Or Black Twin Parallel Wire 0.15x11 |
1100 Ω |
3900 K |
R-T | ||
2000 Ω |
3560 K |
R-T | ||
2100 Ω |
3900 K |
R-T | ||
2300 Ω |
3560 K |
R-T | ||
2800 Ω |
3900 K |
R-T | ||
3 kΩ |
3820 K |
R-T | ||
5 kΩ |
3970 K |
R-T | ||
10 kΩ |
3970K |
R-T | ||
10 kΩ |
3435 K |
R-T | ||
30 kΩ |
4000 K |
R-T | ||
50 kΩ |
4000 K |
R-T | ||
20 kΩ |
3970 |
R-T | ||
50 kΩ |
3970 K |
R-T | ||
100 kΩ |
3970 K | R-T | ||
200 kΩ |
3970 K | R-T | ||
170 kΩ |
4250 K |
R-T |
Ordering Codes for AC Sensor Type NTC Thermistors
STTS *** R# %% @ L$$$ &&&&
*** = Resistance Value at 25°C (eg: 102- 1000Ω, 201 - 200Ω, 103 – 10kΩ)
# = Resistance Tolerance (eg: R1 - ± 1%, R5 - ±5%)
%% = Encapsulation (eg : M3 – 3mm Brass Ring Terminal)
@ = Type of Lead
$$$ = Total Length in mm (eg : L251 – 250mm Length, L401 – 400 mm Length)
&&&& = Beta Value (eg: 3977-3977K, 3830 – 3830K)
Encapsulation
MT –Metal Tube (SS 5x25 ,6x25 Etc)
PT – Plastic Tube
EC – Epoxy Coated
FT – Flag Type
SP – Special Type
Type of Lead
A – Blue/ Yellow PTFE Insulated Silver Plated Multistanded Copper Wire AWG 24
B – Blue/ Yellow PTFE Insulated Silver Plated Multistanded Copper Wire AWG 26
C – Blue/ Yellow PTFE Insulated Silver Plated Multistanded Copper Wire AWG 28
D – Blue/ Yellow PTFE Insulated Silver Plated Multistanded Copper Wire AWG 30
E – Twin Parallel Wire Black